- ibidi气体孵育系统-11920 11922 11929
详细信息
品牌:德国ibidi 加工定制:否 型号:11920 11922 11929 规格型号:11920 11922 11929 货号
产品名称
规格(个/盒)
11920
ibidi CO2气体控制系统
1
11922
ibidi CO2和O2气体控制系统
1
11929
ibidi 气体压力泵
1
Applications:
1.Live cell imaging that requires incubator conditions on the microscope, for example:
- Chemotaxis
- Angiogenesis
- Cell migration, proliferation, wound healing
- Cell culture under flow2.Imaging applications with extra focus stability, for example:
- TIRF
- Confocal microscopy3.Anaerobic conditions or oxidative stress
Technical Features:1.Precise and reliable gas incubation for O2 and CO2
2.Active and fast humidification - no evaporation
3.Uses pressurized air to create the gas flow – no vibrations
4.Optional air pressure generator available (for when pressurized air is not obtainable)
The ibidi Gas Incubation System provides both humid and CO2-rich air for stage-top incubators like the ibidi Heating System. The gas mixture is continuously flushed through the stage top incubator, ensuring a maximum humidity and an optimal pH for CO2-buffered liquids.
Spheroid of breast cancer cells with living cells (green) and apoptotic center (red) due to oxygen depletion.
Components of the ibidi Gas Incubation System
ibidi Gas Mixer for CO2 and O2
1.Precise and reliable gas incubation
2.Active and fast humidification without evaporation (patent pending technology)
3.Suitable for various experimental conditions (e.g., pH or hypoxia)
4.Fully compatible with the ibidi Heating Systems
5.Uses pressurized air to create the gas flow – no vibrations
6.Optional air pressure generator available (for when pressurized air is not obtainable)
Humidifying Column
1.Part of the ibidi Gas Incubation System
2.Humidifies the outgoing CO2 / O2 / air mix to minimize sample evaporation
3.Active humidity control inside the attached ibidi Heating System
The ibidi Gas Incubation System upgrades your ibidi Heating System to a complete stage top incubator.
Location/Tissue Oxygen Partial Pressure p(O2) Corresponding O2 in
Cell Culture Gas Mix (%)Inspired air 21 kPa (=160 mm Hg) 21% Alveolus 14 kPa (=104 mm Hg) 14% Arterial blood 14 kPa (=104 mm Hg) 14% Veneous blood 5 kPa (=40 mm Hg) 5% Interstitial fluid 5 kPa (=40 mm Hg) 5% Healthy tissue 2-3 kPa (=15- 23 mm Hg) 2-3% Tumor without blood vessels Outside 1 kPa (=7.5 mm Hg) 1% Center 0 kPa (=0 mm Hg) 0% Normoxia conditions 2 - 11 kPa (=15 - 82 mm Hg) 2-11% Hypoxia conditions 0 - 1 kPa (=0 - 7.5 mm Hg) 0-1% Cell culture incubator (5% CO2) 20 kPa (=150 mm Hg) 20% ibidi Gas Incubation System
Compatible with:
1.ibidi Heating System, Universal Fit
2.ibidi Heating System, Multi-Well Plates
-